Tublin ® 35
DATA SHEET
Application
It has improved seal abilities and easy opening, as well as closed against bacteria.
A product packed in TUBLIN® 35 will dry quicker than without any packaging.
Specifications | |
Lay flat size: | 50-400 mm – tolerance ±1 mm |
Wall thickness: | 40-80µ – tolerance ±10% |
Length: | 300-1800 mm |
Temperature: | -40°C up to 140°C |
Property | Typical Value | Standard |
Density | 1.04 g/cm³ | ISO R1183 |
Melting Point | 170°C | ASTM D 3418 |
Oxygen Transmission | ||
Water Vapour | 5000 g/50µ/m²/24h (38°C/50%RH) | ASTM E 96 BW |
Handling | |
Sealing: | Needs high sealing temperature. |
Filing: | It is important to have contact between film and product. |
Storage: | Dark, below 25 °C and 75% RH. Should be used within one year from date of production. |
Remarks
TUBLIN® 35 is not a packaging material. It is a process help which improves safety and yields. Unwanted air pockets will be avoided, if the product is vacuumed in TUBLIN® 35. A product packed in TUBLIN® 35 will dry quicker than without any packaging.TUBLIN® 35 is closed against bacteria and mould.
Certification
TUBLIN® meets the requirements in EU regulation No. 10/2011/EC as amended by regulation No. 321/2011/EC, No. 1282/2011/EC and No. 1183/2012/EC on plastic material and articles intended to come into contact with food for the above mentioned test conditions.
Global migration based on executed test made with:
Method Nor. EN 1186-4: | Exposure to olive oil by pouccell. Gravimetric + GC/FID determination Limit of detection: 2 mg/dm2 |
Method Nor. EN 1186-5: | Exposure to 10% ethanol by cell. Gravimetric determination Limit of detection: 1 mg/dm2 |
Specific migration based on executed test made with:
Method Nor. EN 13130: | Solvent dissolution and determination by GC/MS |
SML: Laurolactam | Limit of detection: 0.3 mg/kg |
It can be used for contact with aqueous and fatty foodstuff with a pH > 4.5.
If used for foodstuff with a pH < 4.5 it must be tested again using a simulant B (Acetic acid 3%).
Note: This statement is provided for your guidance only and no warranties on your final products. Because the conditions of commercial use are not under our control, therefore migration tests on the finished package are needed for reconfirmation by the user.